Fully Enclosed Circular Electrocoagulation System , Electrocoaggulation Electrolysis Machine , Air Flotation Machine ,

Fully Enclosed Circular Electrocoagulation System , Electrocoaggulation Electrolysis Machine , Air Flotation Machine ,

Ask Latest Price
Brand Name :Loren
Model Number :REF seris (1-50)
Certification :ISO
Place of Origin :CHINA
MOQ :1
Payment Terms :T/T, Western Union, MoneyGram, , L/C
Supply Ability :50 sets per month
Delivery Time :30 days for containerized order
Packaging Details :poly or wooden box or as per demand
Color :Main Host can be customized
Electrode :Aluminium, Titanium , SS, iron etc optional as per water data
Design :Modules Design optional for power supply e-box, main host and electrode assembly sets
Cost of Invest and Run or Maintenance :cheaper for long time running ,only change electrode plates
More we can do :total EC solutin , or Total Waste water ZLD solution
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description
    1. Ectrocoagulation, Electrooxidation , Electroperoxi-coagulation
    2. Fully Enclosed Circular Electrocoagulation & Electroflotation Dissolved Air Flotation Equipment

      Fully Enclosed Circular Electrocoagulation System , Electrocoaggulation Electrolysis Machine , Air Flotation Machine ,

      Brief of EC or EF Tech and Method

Electrocoaggulation or Electroflocculation Process can be used alone or in combination with other treatment methods to rapidly improve the biodegradability of Industrial wastewater such as refractory organic wastewater in pharmaceutical, chemical, fuel industry esp. for toxic substances , Heavy metal, emulsified organic matter excellent removal efficiency.

Fully Enclosed Circular Electrocoagulation System , Electrocoaggulation Electrolysis Machine , Air Flotation Machine ,

Outstanding Characteristic and Feature

1.Adapt to a Wide Range of Wastewater to Handle a Variety of Pollutants

2.30-Year Applied Unique Special Electrodes Layout with No Blocking

3.Electrodes Last for 100 to 250 days as per different Site Condition

4.Low Investment Costs with High Volume Throughut

5.Low Operating Costs

6.Low Maintenance and Repair Costs

7.No Need to add Any Chemicals

8.Small Footprint

9.Simple Operation and High Degree Of Automation

10.Short Processing Time and High Processing Efficiency

11.Equipment Processing Produces Less Sludge And Sludge

Fully Enclosed Circular Electrocoagulation System , Electrocoaggulation Electrolysis Machine , Air Flotation Machine ,

Applicant

1. High Concentration Organic Wastewater

2. High Ammonia Nitrogen Wastewater

3.Electroplating Wastewater (Including Heavy Metals)

4. Fluorine- Containing Wastewater

5. Dying and Printing (High Chroma) Wastewater Treatment

6. Paper Mill Pretreament

7.Shipyard Waste Water

8.Oily Water Treatment

9.Agriculture Breeding Waste Water

10.Aquaculture Pig Farm Waste Water Pretreatment

11.Electrolytic Manganese Wastewater

12. Emulsified Liquid Waste Water Pretreatment

Fully Enclosed Circular Electrocoagulation System , Electrocoaggulation Electrolysis Machine , Air Flotation Machine ,

13. Landfill Leachate Waste Water Disposal

14. Integrated Waste Water Pretreatment

15.Circuit Board Wastewater

16. Rare Earth Materials Processing Waste Water

17. Aquarium One Year No Changing Water Solution

Fully Radical Electrocoaggulation System Reference Parameter Table

Model Flow Power Outline Dimension (mm) Area (M2) Lifter
Main Host Power Cabinet Auto Float Slot Minimum
REF-1 1.0m3/h 4.5kW Φ450*1300 600*400*1500 Φ800*1600 5 None
REF-5 5.0m3/h 15kW Φ820*2000 800*600*1700 Φ1400*2400 18 0.5t
REF-10 10.0m3/h 25kW Φ820*2300 900*600*1800 Φ1900*2400 24 0.5t
REF-30 30.0m3/h 60kW Φ1380*2400 1300*800*2200 Φ2900*2800 40 1.0t
REF-50 50.0m3/h 90kW Φ1380*2900 1500*900*2500 Φ4000*2800 60 1.0t

Equipment Operating Cost

Electricity Consumption: 0.1-1.5kWh/ ton As per Different Waste Water

Electrode Plate Loss: USDS 0.0014-0.0043 / M3 Water.

Electric Flocculation Operation Cost: USDS 0.0086-0.1122/M3 Water. (Electricity Price Calculated as USDS 0.072 / kW)

Fully Enclosed Circular Electrocoagulation System , Electrocoaggulation Electrolysis Machine , Air Flotation Machine ,

Installation Method

The Electrocoagulation Machine can be installed at the location near the treatment site, and the power control cabinet should be placed in the drying equipment room. If there are special explosion-proof requirements, it needs to be explained in advance.

Method of Operation

The Electrofluculation Machine is a continuous automatic operation mode, and no special care is required. The water inlet is provided with a flow meter, and the flow rate can be controlled by the valve. The water is pressurized by the pump into other processing systems, or directly discharged, and the equipment discharge can be set to manual or automatic control according to requirements.

Fully Enclosed Circular Electrocoagulation System , Electrocoaggulation Electrolysis Machine , Air Flotation Machine ,

Precautions

1.When the Electrofluculation System is not in use, It cannot be energized to avoid danger and equipment damage.

2.Do not arbitrarily power off when the equipment is working through water.

3.Do not touch the voltage output when powering up to avoid danger.

4.Keep the heat sink well ventilated when the device is powered.

5.The electrical parts must not be watered or wrapped in plastic cloth or likewise.

6.The Electrocoagulation equipment must be shut down before servicing.

Fully Enclosed Circular Electrocoagulation System , Electrocoaggulation Electrolysis Machine , Air Flotation Machine ,

7. If the subsequent process or equipment has been fouled, the treated process or equipment should be drained once every 2 hours, no less than 3 minutes each time; and the dirt should be cleaned regularly to prevent the residue from clogging the equipment and causing an accident.

8. Do not rub hard when loading or unloading equipment.

Touch us freely

Bruce Xiong / Peter Lee

Owner/Marketing Director

Loren Industry Co., Ltd

Water Care and Energy Expert for 16 years

What app /WeChat/ mobile: +86-13921106199 or 13952466865

Skype: Ginkeneer or peterlee4778

Mail: lorenindustry@163.com or Lorenindustry@126.com

web: www.lorenindustry.com or www.lorenenvirotech.com

One Time Trust , Long Lasting Rewarding

Fully Enclosed Circular Electrocoagulation System , Electrocoaggulation Electrolysis Machine , Air Flotation Machine ,

China Fully Enclosed Circular Electrocoagulation System , Electrocoaggulation Electrolysis Machine , Air Flotation Machine , for sale

Fully Enclosed Circular Electrocoagulation System , Electrocoaggulation Electrolysis Machine , Air Flotation Machine ,

Inquiry Cart 0